Evaluating Commercial Control Materials and Homemade Lyophilisates Quality in Kidney Function Test with Sigma Metric

Alifa Christin (1) , Alifa Christin (2) , Anik Handayati (3)
(1) a:1:{s:2:"en";s:28:"Poltekkes Kemenkes Surabaya ";},
(2) Poltekkes Kemenkes Surabaya ,
(3) Poltekkes Kemenkes Surabaya

Abstract

This study aims to determine the quality of commercial control materials and homemade lyophilisates using the sigma metric method for BUN and creatinine parameters in a primary clinical laboratory. This cross-sectional study conducted 20 examinations on both types of control materials. The results showed that for the BUN parameter, homemade lyophilisates had a sigma value of 1 (unacceptable), while the commercial control material had a sigma value of 2 (poor). For the creatinine parameter, both homemade lyophilisates and commercial control materials had a sigma value of 3 (marginal). There was a significant difference in quality between commercial control materials and homemade lyophilisates for the BUN parameter, so homemade lyophilisate cannot be used as an alternative to commercial control materials. However, for the creatinine parameter, there was no significant difference in quality between the two control materials, so homemade lyophilisates can be used as an alternative to commercial control materials. Thus, this study shows that homemade lyophilisates can be an effective and economical alternative for creatinine parameters, but not for BUN parameters. This research can help primary clinical laboratories to develop more effective and efficient quality control strategies.

Full text article

Generated from XML file

Authors

Alifa Christin
christinalifa@gmail.com (Primary Contact)
Alifa Christin
Anik Handayati
Author Biographies

Alifa Christin , a:1:{s:2:"en";s:28:"Poltekkes Kemenkes Surabaya ";}

Name : Alifa Christin 

Place and date of birth : Gresik, 19 March 2003

Phone number : 085815872520

Alifa Christin , Poltekkes Kemenkes Surabaya

Name : Alifa Christin 

Place and date of birth : Gresik, 19 March 2003

Phone number : 085815872520

Anik Handayati , Poltekkes Kemenkes Surabaya

Corresponding author

[1]
“Evaluating Commercial Control Materials and Homemade Lyophilisates Quality in Kidney Function Test with Sigma Metric”, International Journal of Advanced Health Science and Technology, vol. 5, no. 4, Aug. 2025, doi: 10.35882/ijahst.v5i4.510.

Article Details

How to Cite

[1]
“Evaluating Commercial Control Materials and Homemade Lyophilisates Quality in Kidney Function Test with Sigma Metric”, International Journal of Advanced Health Science and Technology, vol. 5, no. 4, Aug. 2025, doi: 10.35882/ijahst.v5i4.510.

Similar Articles

You may also start an advanced similarity search for this article.