Microcontrollers Performance in Portable Electronic Stethoscope Design with a Disease Symptoms Detection Feature
Abstract
One of the early examinations that is often done is to detect heart disease using a stethoscope. The electronic stethoscope consists of a membrane and tube from a conventional stethoscope coupled with a condenser microphone which is then connected to a computer. The purpose of this study is to analyze the comparison of two types of microcontrollers in the design of a portable electronic stethoscope equipped with a symptom detector. The research method used is instrumentation with 2 types of microcontrollers to design a heart sound detector. In processing the data to be displayed on the 16x2 Character LCD. Sending heart signal data for 60 seconds to produce BPM data which is processed using 2 different types of microcontrollers. The results of data collection on battery consumption of power usage on the AT mega 2560 resulted in an average saving of 0.11W. Therefore, it can be concluded that the two stethoscopes have a significant difference when compared, where the Arduino Mega 2560 is able to process data from heart signals faster than the AT mega 328P. The results of the research that have been carried out can be implemented using a system that strongly supports the needs when checking heart sound signals
Full text article
References
K. Pariaszewska, M. Młyńczak, W. Niewiadomski, and G. Cybulski, “Digital stethoscope system: the feasibility of cardiac auscultation,” Photonics Appl. Astron. Commun. Ind. High-Energy Phys. Exp. 2013, vol. 8903, p. 890315, 2013, doi: 10.1117/12.2032161.
S. Swarup and A. N. Makaryus, “Digital stethoscope: Technology update,” Med. Devices Evid. Res., vol. 11, pp. 29–36, 2018, doi: 10.2147/MDER.S135882.
F. S. M. Lisboa et al., “Electronic stethoscope – a didactic and low cost acquisition system for auscultation,” Int. J. Biosens. Bioelectron., vol. 5, no. 5, pp. 160–164, 2019, doi: 10.15406/ijbsbe.2019.05.00171.
Y. Antonisfia and R. Wiryadinata, “Ekstraksi Ciri pada Isyarat Suara Jantung Menggunakan Power Spectral Density Berbasis Metode Welch,” Media Inform., vol. 6, no. 1, pp. 71–84, 2008, doi: 10.20885/informatika.vol6.iss1.art5.
J. P. Ángel-López and N. Arzola de la Peña, “VII Latin American Congress on Biomedical Engineering CLAIB 2016, Bucaramanga, Santander, Colombia, October 26th -28th, 2016,” IFMBE Proc., vol. 60, pp. 520–523, 2017, doi: 10.1007/978-981-10-4086-3.
S. Leng, R. S. Tan, K. T. C. Chai, C. Wang, D. Ghista, and L. Zhong, “The electronic stethoscope,” Biomed. Eng. Online, vol. 14, no. 1, 2015, doi: 10.1186/s12938-015-0056-y.
S. Biswas, “Design and Implementation of a PC based Electronic Stethoscope,” vol. 9, no. 10, pp. 207–213, 2013, doi: 10.5614/jts.2013.19.3.7.
C. Ahlström, Processing of the Phonocardiographic Signal − Methods for the Intelligent Stethoscope, no. 1253. 2006.
K. Patil, “Design of Wireless Electronic Stethoscope Based on Zigbee,” Int. J. Distrib. Parallel Syst., vol. 3, no. 1, pp. 351–359, 2012, doi: 10.5121/ijdps.2012.3130.
H. Uǧuz et al., “ce pte d M us pt,” J. Phys. Energy, vol. 2, no. 1, pp. 0–31, 2020, doi:10.35882/ieee.v2il.7.
A. Jain, R. Sahu, A. Jain, T. Gaumnitz, P. Sethi, and R. Lodha, “Development and validation of a low-cost electronic stethoscope: Diy digital stethoscope,” BMJ Innov., no. 8, 2021, doi: 10.1136/bmjinnov-2021-000715.
C. Aguilera-Astudillo, M. Chavez-Campos, A. Gonzalez-Suarez, and J. L. Garcia-Cordero, “A low-cost 3-D printed stethoscope connected to a smartphone,” Proc. Annu. Int. Conf. IEEE Eng. Med. Biol. Soc. EMBS, vol. 2016-October, pp. 4365–4368, 2016, doi: 10.1109/EMBC.2016.7591694.
M. E. H. Chowdhury et al., “Real-time smart-digital stethoscope system for heart diseases monitoring,” Sensors (Switzerland), vol. 19, no. 12, 2019, doi: 10.3390/s19122781.
Y. N. Khurniawan, T. Hamzah, and D. Titisari, “Stetoskop Elektronik Sederhana untuk Auskultasi Jantung dan Paru,” 2017, 10.56346/ijeeemi.v2il.7.
Y. J. Jo, T. H. Nguyen, and D. C. Lee, “Condition monitoring of submodule capacitors in modular multilevel converters,” 2014 IEEE Energy Conversion Congress and Exposition, ECCE 2014. pp. 2121–2126, 2014, doi: 10.1109/ECCE.2014.6953683.
A. Rizal, “Stetoskop Elektronik Sederhana Berbasis PC dengan Fasillitas Pengolahan Sinyal Digital untuk Auskultasi Jantung dan Paru,” no. January 2015, pp. 236–239, 2006.
A. I. Diwi, R. R. Mangkudjaja, and I. Wahidah, “Analisis Kualitas Layanan Video Live Streaming pada Jaringan Lokal Universitas Telkom,” Bul. Pos dan Telekomun., vol. 12, no. 3, p. 207, 2015, doi: 10.17933/bpostel.2014.120304.
R. C. Pratama, E. S. Pramukantoro, and A. Basuki, “Pengembangan Interface Bluetooth Low Energy ( BLE ) Pada IoT Middleware Untuk Mendukung Network Interoperability,” J. Pengemb. Teknol. Inf. dan Ilmu Komput. Univ. Brawijaya, vol. 2, no. 10, pp. 4020–4026, 2018.
P. Oktivasari, “Perancangan Stetoskop Elektronik Berbasis Komputer dengan Akuisisi Data Menggunakan NI-DAQ Card,” J. Fis. FLUX, vol. 7, no. 2, pp. 177–184, 2010.
R. N. Ritonga, T. Hamzah, and Moch. Prastawa Assalim, “Stetoskop Wireless dengan Output Grafik dan Suara Tamppil Personal Computer (PC),” p. 11, 2017, doi: 10.1234/jeeemi.v1lil.9..
H. Vieira, N. Costa, L. P. Coelho, and J. Alves, “Real-time modeling of abnormal physiological signals in a phantom for bioengineering education,” IEEE Glob. Eng. Educ. Conf. EDUCON, vol. 2020-April, no. 14, pp. 1206–1211, 2020, doi: 10.1109/EDUCON45650.2020.9125155.
J. Jusak and I. Puspasari, “Wireless tele-auscultation for phonocardiograph signal recording through Zigbee networks,” APWiMob 2015 - IEEE Asia Pacific Conf. Wirel. Mob., pp. 95–100, 2016, doi: 10.1109/APWiMob.2015.7374939.
C. Saxena, A. Sharma, R. Srivastav, and H. K. Gupta, “Denoising of ECG signals using FIR & IIR filter: A performance analysis,” Int. J. Eng. Technol., vol. 7, no. 4.12 Special Issue 12, pp. 1–5, 2018, doi: 10.14419/ijet.v7i4.12.20982.
G. H. Prabowo, M. R. Mak’ruf, S. Sumber, L. Soetjiatie, and B. Utomo, “Perancangan Stetoskop Elektronik Portable”, Teknokes, vol. 12, no. 1, pp. 39-44, Sep. 2019.
S. Sumber and E. Dian S., “Rancang Bangun Stetoscope Elektronik Berbasis Mikrokontroller Atmega328”, Teknokes, vol. 12, no. 2, pp. 64-68, Feb. 2021.
Authors
Copyright (c) 2021 Torib Hamzah Hamzah, Endang Dian Setioningsih, Sumber Sumber

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Authors who publish with this journal agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution-ShareAlikel 4.0 International (CC BY-SA 4.0) that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).