Enhancement Drip Dose Infusion Accuracy Based on Optocoupler and Microcontroller Sensor

Authors

DOI:

https://doi.org/10.35882/ijahst.v2i4.135

Abstract

Setting the speed of infusion drops in a manual manner is by adjusting the clamp on the infusion set, where the nurse must count the number of infusion drops in the chamber at the same time as looking at the time on the watch. This makes the setting is subjective and cannot be shown with numbers. In addition, nurses cannot monitor the infusion rate continuously. Therefore, it is necessary to enhancement the accuracy of giving infusion drops so that they can be objective and can be shown with numbers and monitor continuously. This enhancement in accuracy is done by making a instrument with an optocoupler to detect infusion drops. For processing uses an arduino microcontroller to be the speed and the volume of infusion and detects changes in the rate of infusion drops significantly. And for the display uses a OLED display and a buzzer as an indicator. The results of this instrument, it can be seen that the optocoupler can detect infusion drops in the infusion set properly. This good sensor reading has implications for accurate readings of the infusion drop rate and infusion drop volume. This enhancement in accuracy is not only for the macro drip (20 drops/cc) but also for the micro drip (60 drops/cc). The accuracy of volume readings ranges from 95-99% for the macro drip and 94.5-97% with the micro drip. And for speed accuracy ranges from 92.37-98.46%. Based from the results of this test, enhancement the accuracy of the infusion drip dose administration can be done by making a patient infusion drip dose calculator. This equipment uses an optocoupler sensor, arduino microcontroller, OLED display and buzzer. With the use of this instrument, nurses can be more accurate in regulating the rate of infusion drops given to patients and can monitor it continuously if there is a significant change in infusion rate.

Downloads

Download data is not yet available.

References

A. P. Pudji, A. M. Maghfiroh, and N. Thongpance, “Design an Infusion Device Analyzer with Flow Rate Parameters using Photodiode Sensor,” Indones. J. Electron. Electromed. Eng. Med. informatics, vol. 3, no. 2, pp. 39–44, 2021, doi: 10.35882/ijeeemi.v3i2.1.

H. Firdaus, B. G. Irianto, Sumber, and J. Lu, “Analysis of the Drop Sensors Accuracy in Central Peristaltic Infusion Monitoring Displayed on PC Based Wireless (TCRT5000 Drop Sensor),” J. Electron. Electromed. Eng. Med. Informatics, vol. 4, no. 1, pp. 42–49, 2022, doi: 10.35882/jeeemi.v4i1.5.

N. Sholihah, A. Kholiq, and S. Sumber, “Monitoring Infusion Pump Via Wireless (Occlusion part),” Indones. J. Electron. Electromed. Eng. Med. informatics, vol. 2, no. 1, pp. 34–41, 2020, doi: 10.35882/ijeeemi.v2i1.7.

D. D. Damayanti, H. G. Ariswati, I. D. G. Wisana, and H. Winarno, “Automatic Dehydration Level Detection Devices,” Indones. J. Electron. Electromed. Eng. Med. informatics, vol. 2, no. 2, pp. 87–94, 2020, doi: 10.35882/ijeeemi.v2i2.5.

N. Jannah, S. Syaifudin, L. Soetjiatie, and M. Irfan Ali, “Simple and Low Cost Design of Infusion Device Analyzer Based on Arduino,” Indones. J. Electron. Electromed. Eng. Med. informatics, vol. 2, no. 2, pp. 80–86, 2020, doi: 10.35882/ijeeemi.v2i2.4.

F. A. D. Saputra, B. Utomo, S. Sumber, and M. Shahriar Arefin, “Development of Measuring Device for Non-Invasive Blood Sugar Levels Using Photodiode Sensor,” Indones. J. Electron. Electromed. Eng. Med. informatics, vol. 2, no. 2, pp. 74–79, 2020, doi: 10.35882/ijeeemi.v2i2.3.

M. Taylor and R. Jones, “Risk of Medication Errors With Infusion Pumps,” Patient Saf., no. December, pp. 61–69, 2019, doi: 10.33940/biomed/2019.12.7.

K. Wright, “Do calculation errors by nurses cause medication errors in clinical practice? A literature review,” Nurse Educ. Today, vol. 30, no. 1, pp. 85–97, 2010, doi: 10.1016/j.nedt.2009.06.009.

J. I. Westbrook, M. I. Rob, A. Woods, and D. Parry, “Errors in the administration of intravenous medications in hospital and the role of correct procedures and nurse experience,” BMJ Qual. Saf., vol. 20, no. 12, pp. 1027–1034, 2011, doi: 10.1136/bmjqs-2011-000089.

N. R. Hardiker and S. Bakken, “Requirements of tools and techniques to support the entry of structured nursing data,” Stud. Health Technol. Inform., vol. 107, no. June 2014, pp. 621–625, 2004, doi: 10.3233/978-1-60750-949-3-621.

P. Y. Han, I. D. Coombes, and B. Green, “Factors predictive of intravenous fluid administration errors in Australian surgical care wards,” Qual. Saf. Heal. Care, vol. 14, no. 3, pp. 179–184, 2005, doi: 10.1136/qshc.2004.010728.

D. H. Cousins, B. Sabatier, D. Begue, C. Schmitt, and T. Hoppe-Tichy, “Medication errors in intravenous drug preparation and administration: A multicentre audit in the UK, Germany and France,” Qual. Saf. Heal. Care, vol. 14, no. 3, pp. 190–195, 2005, doi: 10.1136/qshc.2003.006676.

F. Report, “Critical Paths for Creating Data Platforms: Patient Safety: Intravenous Infusion Pump Devices,” p. 93, 2012.

P. T. Lee, F. Thompson, and H. Thimbleby, “Analysis of infusion pump error logs and their significance for health care.,” Br. J. Nurs., vol. 21, no. 8, pp. S12, S14, S16-20, Apr. 2012, doi: 10.12968/bjon.2012.21.Sup8.S12.

U. of S. Australia, “Drops per minute ( DPM ) - Worksheet,” pp. 1–4.

S. Syaifudin, M. Ridha Mak’ruf, S. Luthfiyah, and S. Sumber, “Design of Two Channel Infusion Pump Analyzer Using Photo Diode Detector,” Indones. J. Electron. Electromed. Eng. Med. informatics, vol. 3, no. 2, pp. 65–69, 2021, doi: 10.35882/ijeeemi.v3i2.5.

C. B. Putra, H. G. Ariswati, S. Sumber, and M. Zahar, “Automatic Blood Collection and Mixer in a Blood Transfusion System Equipped with Barrier Indicators,” Indones. J. Electron. Electromed. Eng. Med. informatics, vol. 2, no. 2, pp. 60–67, 2020, doi: 10.35882/ijeeemi.v2i2.1.

M. P. Assalim T P, D. Titisari, W. Caesarendra, and B. A. Prakoso, “Analysis of the Effect of Red LED and Infrared Flip Flop Frequency on SpO2 Measurement Accuracy,” Indones. J. Electron. Electromed. Eng. Med. Informatics, vol. 4, no. 2, pp. 62–67, 2022, doi: 10.35882/ijeeemi.v4i2.3.

A. G. Anjani et al., “Application of IoT Using nodeMCU ESP8266 on the Syringe Pump Device to Increase Patient Safety,” Indones. J. Electron. Electromed. Eng. Med. Informatics, vol. 4, no. 1, pp. 23–27, 2022, doi: 10.35882/ijeeemi.v4i1.4.

K. K. Giuliano and C. Niemi, “The urgent need for innovation in I.V. Smart pumps,” Nurs. Manage., vol. 46, no. 3, pp. 17–19, 2015, doi: 10.1097/01.NUMA.0000461066.79777.06.

M. Husch et al., “Insights from the sharp end of intravenous medication errors: Implications for infusion pump technology,” Qual. Saf. Heal. Care, vol. 14, no. 2, pp. 80–86, 2005, doi: 10.1136/qshc.2004.011957.

E. T. Pierce, V. Kumar, H. Zheng, and R. A. Peterfreund, “Medication and volume delivery by gravity-driven micro-drip intravenous infusion: potential variations during ‘wide-open’ flow.,” Anesth. Analg., vol. 116, no. 3, pp. 614–618, Mar. 2013, doi: 10.1213/ANE.0b013e31827bc235.

E. D. Kurniawan, A. Adam, M. I. Salik, and P. L. Gareso, “Programmable Syringe Pump for Selective Micro Droplet Deposition,” J. Elektron. dan Telekomun., vol. 19, no. 2, p. 75, 2019, doi: 10.14203/jet.v19.75-82.

S. Zheng, Z. Li, and B. Li, “The design of liquid drip speed monitoring device system based on MCU,” AIP Conf. Proc., vol. 1864, no. August, 2017, doi: 10.1063/1.4992940.

V. Wirtz, “9-Wirtz2003 (9),” 2003.

L. F. Wakidi, K. Maulidya S. P, and M. Nosike, “Electronic Infusion Flow Regulator with Occlusion Detection,” J. Teknokes, vol. 15, no. 1, pp. 14–20, 2022, doi: 10.35882/teknokes.v15i1.3.

T. Mulyono and U. Faruq, “Desain Pompa Multi Syringe Untuk Analisa Sistem Alir D esign of Multi Syringe Pump for Flow System Analysis,” vol. 14, no. 1, pp. 17–21, 2013.

M. C. Layson, “Intravenous (IV) monitoring and refilling system,” Int. J. Eng. Adv. Technol., vol. 9, no. 1, pp. 3038–3043, 2019, doi: 10.35940/ijeat.A1613.109119.

K. K. Thariyan, S. Verma, S. R. Taneja, R. C. Gupta, and S. S. Ahluwalia, “Design and development of a unique drop sensing unit for infusion pump,” J. Sci. Ind. Res. (India)., vol. 61, no. 10, pp. 798–801, 2002.

K. K. Giuliano, “IV Smart Pumps: The Impact of a Simplified User Interface on Clinical Use,” Biomed. Instrum. Technol., no. December, pp. 13–21, 2015, doi: 10.2345/0899-8205-49.s4.13.

D. Qiliang, L. Jianhao, and T. Lianfang, “Simulation and Design of Intravenous Infusion Dripping Rate Detection based on Infrared Ray,” Proc. 3rd Int. Conf. Multimed. Technol., vol. 84, no. Iv, pp. 918–925, 2013, doi: 10.2991/icmt-13.2013.113.

S. Hossain, S. Sharmin, T. Faruk, and M. K. Islam, “Low-Cost Digitization of Infusion Pump for Real-time Automated Flow Rate Monitoring and Warning,” ICIET 2019 - 2nd Int. Conf. Innov. Eng. Technol., pp. 23–24, 2019, doi: 10.1109/ICIET48527.2019.9290599.

P. Saputra, Syamsuddin, and Hiden, “Indonesian Physical Review,” Indones. Phys. Rev., vol. 4, no. 1, pp. 43–50, 2021.

Downloads

Published

2022-08-25

How to Cite

[1]
Yudistira Marsya Puvindra, Arief Marwanto, Eka Nuryanto Budisusila, and V. . Abdullayev, “Enhancement Drip Dose Infusion Accuracy Based on Optocoupler and Microcontroller Sensor”, International Journal of Advanced Health Science and Technology, vol. 2, no. 4, pp. 267–273, Aug. 2022.

Issue

Section

Medical Engineering and Technology